CallerID

Caller-ID DTMF FSK

 

  1. PR Rowenta
  2. Panasonic -TCD715 8
  3. Panasonic KX-TCD215RU 1
  4. Panasonic -TCD121RU 1
  5. Panasonic -TG8105RU 1
  6. Panasonic TCD700
  7. Panasonic TCD650
  8. Panasonic TCD410
  9. Panasonic TCD1484
  10. Panasonic TCD450RU 8
  11. Panasonic --363
  12. Panasonic -146RUS
  13. Panasonic -TCD725RU
  14. Panasonic -TCD755RU
  15. Panasonic -148
  16. Panasonic -143RUW
  17. Panasonic -510RUW
  18. Panasonic --362
  19. Panasonic TSC10
  20. GE-6963
  21. GE-9393
  22. GE-9391
  23. GE-9398
  24. DIALON F-10
  25. SANIO-CLT-D30
  26. SIEMENS S-150
  27. SIEMENS T-150
  28. ATLINKC 2785062-A
  29. ALCATEL SPR 5100
  30. PANAFONE 10LMSID
  31. Siemens Gigaset 3010(3015) 8
  32. Siemens Gigaset 350 8
  33. Siemens SL-740 8
  34. Siemens Gigaset A-200 8
  35. Siemens Gigaset 450 8

1

< SLC:MODE=1:IDX=1;

LOADING PROGRAM VERSION 23.13-0

CNDFIL INDEX: 1

SID ... SIGNALLING HEADER Display unit 1: BR

SPR ... SENDING PROTOCOL 0

SIN ... SENDING INSTANT 0

ISE ... INCOMPLETE SENDING 1

NLE ... NUMBERS LENGTH 16

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 0

SEO ... SENDING ORDER -

BSS ... B-SUBSCRIBER SEND -

STS ... START SIGNALS -

SSC ... START SIGNALS FORWARDED CALL -

SCS ... SPACE SIGNALS -

SPS ... STOP SIGNALS -

RES ... RESTRICT SIGNALS B10C

NAS ... NOT AVAILABLE SIGNALS B00C

AAT ... AFTER ANSWER TIMEOUT -

ART ... AFTER FIRST RINGING TIMEOUT 6

POL ... POLARITY REVERSAL 0

9

< SLC:MODE=1:IDX=9;

LOADING PROGRAM VERSION 23.13-0

CNDFIL INDEX: 9

SID ... SIGNALLING HEADER ETSI-2

SPR ... SENDING PROTOCOL 3

SIN ... SENDING INSTANT 1

ISE ... INCOMPLETE SENDING 1

NLE ... NUMBERS LENGTH 14

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 2

SEO ... SENDING ORDER -

BSS ... B-SUBSCRIBER SEND -

STS ... START SIGNALS -

SSC ... START SIGNALS FORWARDED CALL -

SCS ... SPACE SIGNALS -

SPS ... STOP SIGNALS -

RES ... RESTRICT SIGNALS F

NAS ... NOT AVAILABLE SIGNALS F

AAT ... AFTER ANSWER TIMEOUT 7

ART ... AFTER FIRST RINGING TIMEOUT 10

POL ... POLARITY REVERSAL -

8

< SLC:MODE=1:IDX=8;

LOADING PROGRAM VERSION 23.13-0

CNDFIL INDEX: 8

SID ... SIGNALLING HEADER ETSI-AFR

SPR ... SENDING PROTOCOL 3

SIN ... SENDING INSTANT 1

ISE ... INCOMPLETE SENDING 1

NLE ... NUMBERS LENGTH 14

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 0

SEO ... SENDING ORDER -

BSS ... B-SUBSCRIBER SEND -

STS ... START SIGNALS -

SSC ... START SIGNALS FORWARDED CALL -

SCS ... SPACE SIGNALS -

SPS ... STOP SIGNALS -

RES ... RESTRICT SIGNALS F

NAS ... NOT AVAILABLE SIGNALS F

AAT ... AFTER ANSWER TIMEOUT 7

ART ... AFTER FIRST RINGING TIMEOUT 16

POL ... POLARITY REVERSAL -

SLC:MODE=1:IDX=1;

CNDFIL INDEX: 1

SID ... SIGNALLING HEADER Display unit 1: BR

SPR ... SENDING PROTOCOL 0

SIN ... SENDING INSTANT 0

ISE ... INCOMPLETE SENDING 0

NLE ... NUMBERS LENGTH 16

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 0

SEO ... SENDING ORDER -

BSS ... B-SUBSCRIBER SEND -

STS ... START SIGNALS -

SSC ... START SIGNALS FORWARDED CALL -

SCS ... SPACE SIGNALS -

SPS ... STOP SIGNALS -

RES ... RESTRICT SIGNALS B10C

NAS ... NOT AVAILABLE SIGNALS B00C

AAT ... AFTER ANSWER TIMEOUT -

ART ... AFTER FIRST RINGING TIMEOUT 6

POL ... POLARITY REVERSAL 0

SLC:MODE=1:IDX=2;

LOADING PROGRAM VERSION 23.12-0

CNDFIL INDEX: 2

SID ... SIGNALLING HEADER Display unit 1: AFR

SPR ... SENDING PROTOCOL 0

SIN ... SENDING INSTANT 1

ISE ... INCOMPLETE SENDING 0

NLE ... NUMBERS LENGTH 16

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 0

SEO ... SENDING ORDER -

BSS ... B-SUBSCRIBER SEND -

STS ... START SIGNALS -

SSC ... START SIGNALS FORWARDED CALL -

SCS ... SPACE SIGNALS -

SPS ... STOP SIGNALS -

RES ... RESTRICT SIGNALS B10C

NAS ... NOT AVAILABLE SIGNALS B00C

AAT ... AFTER ANSWER TIMEOUT -

ART ... AFTER FIRST RINGING TIMEOUT 6

POL ... POLARITY REVERSAL -


SLC:MODE=1:IDX=3;

LOADING PROGRAM VERSION 23.12-0

CNDFIL INDEX: 3

SID ... SIGNALLING HEADER Display unit 2: BR

SPR ... SENDING PROTOCOL 0

SIN ... SENDING INSTANT 0

ISE ... INCOMPLETE SENDING 0

NLE ... NUMBERS LENGTH 16

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 2

SEO ... SENDING ORDER 0

BSS ... B-SUBSCRIBER SEND 1

STS ... START SIGNALS A

SSC ... START SIGNALS FORWARDED CALL A

SCS ... SPACE SIGNALS D

SPS ... STOP SIGNALS C

RES ... RESTRICT SIGNALS B10C

NAS ... NOT AVAILABLE SIGNALS B00C

AAT ... AFTER ANSWER TIMEOUT -

ART ... AFTER FIRST RINGING TIMEOUT 6

POL ... POLARITY REVERSAL 0

SLC:MODE=1:IDX=4;

LOADING PROGRAM VERSION 23.12-0

CNDFIL INDEX: 4

SID ... SIGNALLING HEADER Display unit 2: AFR

SPR ... SENDING PROTOCOL 0

SIN ... SENDING INSTANT 1

ISE ... INCOMPLETE SENDING 0

NLE ... NUMBERS LENGTH 16

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 2

SEO ... SENDING ORDER 0

BSS ... B-SUBSCRIBER SEND 1

STS ... START SIGNALS A

SSC ... START SIGNALS FORWARDED CALL A

SCS ... SPACE SIGNALS D

SPS ... STOP SIGNALS C

RES ... RESTRICT SIGNALS B10C

NAS ... NOT AVAILABLE SIGNALS B00C

AAT ... AFTER ANSWER TIMEOUT -

ART ... AFTER FIRST RINGING TIMEOUT 6

POL ... POLARITY REVERSAL -


SLC:MODE=1:IDX=5;

LOADING PROGRAM VERSION 23.12-0

CNDFIL INDEX: 5

SID ... SIGNALLING HEADER Display unit 3:BT227

SPR ... SENDING PROTOCOL 1

SIN ... SENDING INSTANT 0

ISE ... INCOMPLETE SENDING 0

NLE ... NUMBERS LENGTH 16

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 2

SEO ... SENDING ORDER 0

BSS ... B-SUBSCRIBER SEND 1

STS ... START SIGNALS -

SSC ... START SIGNALS FORWARDED CALL -

SCS ... SPACE SIGNALS -

SPS ... STOP SIGNALS -

RES ... RESTRICT SIGNALS P

NAS ... NOT AVAILABLE SIGNALS O

AAT ... AFTER ANSWER TIMEOUT -

ART ... AFTER FIRST RINGING TIMEOUT 5

POL ... POLARITY REVERSAL -

SLC:MODE=1:IDX=6;

LOADING PROGRAM VERSION 23.12-0

CNDFIL INDEX: 6

SID ... SIGNALLING HEADER Display unit 3:FR BR

SPR ... SENDING PROTOCOL 0

SIN ... SENDING INSTANT 0

ISE ... INCOMPLETE SENDING 0

NLE ... NUMBERS LENGTH 16

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 0

SEO ... SENDING ORDER -

BSS ... B-SUBSCRIBER SEND -

STS ... START SIGNALS A

SSC ... START SIGNALS FORWARDED CALL A

SCS ... SPACE SIGNALS D

SPS ... STOP SIGNALS C

RES ... RESTRICT SIGNALS B10C

NAS ... NOT AVAILABLE SIGNALS B00C

AAT ... AFTER ANSWER TIMEOUT -

ART ... AFTER FIRST RINGING TIMEOUT 6

POL ... POLARITY REVERSAL 0


SLC:MODE=1:IDX=7;

LOADING PROGRAM VERSION 23.12-0

CNDFIL INDEX: 7

SID ... SIGNALLING HEADER Display unit 3:FR AF

SPR ... SENDING PROTOCOL 0

SIN ... SENDING INSTANT 1

ISE ... INCOMPLETE SENDING 0

NLE ... NUMBERS LENGTH 16

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 0

SEO ... SENDING ORDER -

BSS ... B-SUBSCRIBER SEND -

STS ... START SIGNALS A

SSC ... START SIGNALS FORWARDED CALL A

SCS ... SPACE SIGNALS D

SPS ... STOP SIGNALS C

RES ... RESTRICT SIGNALS B10C

NAS ... NOT AVAILABLE SIGNALS B00C

AAT ... AFTER ANSWER TIMEOUT -

ART ... AFTER FIRST RINGING TIMEOUT 6

POL ... POLARITY REVERSAL -

SLC:MODE=1:IDX=8;

LOADING PROGRAM VERSION 23.12-0

CNDFIL INDEX: 8

SID ... SIGNALLING HEADER GE29393

SPR ... SENDING PROTOCOL 1

SIN ... SENDING INSTANT 0

ISE ... INCOMPLETE SENDING 1

NLE ... NUMBERS LENGTH 16

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 0

SEO ... SENDING ORDER 0

BSS ... B-SUBSCRIBER SEND 0

STS ... START SIGNALS -

SSC ... START SIGNALS FORWARDED CALL -

SCS ... SPACE SIGNALS -

SPS ... STOP SIGNALS -

RES ... RESTRICT SIGNALS F

NAS ... NOT AVAILABLE SIGNALS F

AAT ... AFTER ANSWER TIMEOUT -

ART ... AFTER FIRST RINGING TIMEOUT 5

POL ... POLARITY REVERSAL -


SLC:MODE=1:IDX=9;

LOADING PROGRAM VERSION 23.12-0

CNDFIL INDEX: 9

SID ... SIGNALLING HEADER ALCATEL

SPR ... SENDING PROTOCOL 0

SIN ... SENDING INSTANT 2

ISE ... INCOMPLETE SENDING 0

NLE ... NUMBERS LENGTH 16

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 0

SEO ... SENDING ORDER -

BSS ... B-SUBSCRIBER SEND -

STS ... START SIGNALS -

SSC ... START SIGNALS FORWARDED CALL -

SCS ... SPACE SIGNALS -

SPS ... STOP SIGNALS -

RES ... RESTRICT SIGNALS B10C

NAS ... NOT AVAILABLE SIGNALS B00C

AAT ... AFTER ANSWER TIMEOUT 50

ART ... AFTER FIRST RINGING TIMEOUT 6

POL ... POLARITY REVERSAL -

SLC:MODE=1:IDX=10;

LOADING PROGRAM VERSION 23.12-0

CNDFIL INDEX: 10

SID ... SIGNALLING HEADER GE_29393

SPR ... SENDING PROTOCOL 1

SIN ... SENDING INSTANT 0

ISE ... INCOMPLETE SENDING 1

NLE ... NUMBERS LENGTH 16

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 2

SEO ... SENDING ORDER -

BSS ... B-SUBSCRIBER SEND -

STS ... START SIGNALS -

SSC ... START SIGNALS FORWARDED CALL -

SCS ... SPACE SIGNALS -

SPS ... STOP SIGNALS -

RES ... RESTRICT SIGNALS P

NAS ... NOT AVAILABLE SIGNALS O

AAT ... AFTER ANSWER TIMEOUT -

ART ... AFTER FIRST RINGING TIMEOUT 5

POL ... POLARITY REVERSAL -


SLC:MODE=1:IDX=11;

LOADING PROGRAM VERSION 23.12-0

CNDFIL INDEX: 11

SID ... SIGNALLING HEADER FSK_POSLE_1_ZV

SPR ... SENDING PROTOCOL 3

SIN ... SENDING INSTANT 1

ISE ... INCOMPLETE SENDING 0

NLE ... NUMBERS LENGTH 16

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 0

SEO ... SENDING ORDER -

BSS ... B-SUBSCRIBER SEND -

STS ... START SIGNALS -

SSC ... START SIGNALS FORWARDED CALL -

SCS ... SPACE SIGNALS -

SPS ... STOP SIGNALS -

RES ... RESTRICT SIGNALS F

NAS ... NOT AVAILABLE SIGNALS F

AAT ... AFTER ANSWER TIMEOUT -

ART ... AFTER FIRST RINGING TIMEOUT 6

POL ... POLARITY REVERSAL -

SLC:MODE=1:IDX=12;

LOADING PROGRAM VERSION 23.12-0

CNDFIL INDEX: 12

SID ... SIGNALLING HEADER FSK_POSLE_1_ZV_2

SPR ... SENDING PROTOCOL 3

SIN ... SENDING INSTANT 1

ISE ... INCOMPLETE SENDING 0

NLE ... NUMBERS LENGTH 16

RDP ... REMOVED DIGITS PLACE 0

SEN ... SENDING NUMBERS 0

SEO ... SENDING ORDER -

BSS ... B-SUBSCRIBER SEND -

STS ... START SIGNALS -

SSC ... START SIGNALS FORWARDED CALL -

SCS ... SPACE SIGNALS -

SPS ... STOP SIGNALS -

RES ... RESTRICT SIGNALS P

NAS ... NOT AVAILABLE SIGNALS O

AAT ... AFTER ANSWER TIMEOUT -

ART ... AFTER FIRST RINGING TIMEOUT 10

POL ... POLARITY REVERSAL -